Diagnostic Error Code
030-196-XXX
SCSI interface test halt, error threshold
exceeded
030-197-XXX
SCSI interface test warning
030-198-XXX
SCSI interface test aborted
030-199-XXX
SCSI interface test failed, cause unknown
035-000-XXX
RAID interface Test Passed
035-0XX-XXX
RAID interface Failure
035-195-XXX
RAID interface Test aborted by user
035-196-XXX
RAID interface test halt, error threshold
exceeded
035-197-XXX
RAID interface test warning
FRU/Action
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility
program," on page 49.
2. Re-run test.
3. Replace the component that is called out
in warning statement.
4. Replace the component under test.
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, "Using the Setup Utility
program," on page 49.
2. Flash the system and re-test. See
"Updating (flashing) the BIOS" on page
167.
3. Go to "Undetermined problems" on
page 81.
1. Go to "Undetermined problems" on
page 81.
2. Flash the system and re-test. See
"Updating (flashing) the BIOS" on page
167.
3. Replace component under function test.
No action
1. RAID signal cable
2. RAID device
3. RAID adapter card, if installed
4. System board
Information only
Restart the test, if necessary.
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility
program," on page 49.
2. Re-run test.
3. Replace the component that is called out
in warning statement.
4. Replace the component under test.
Chapter 8. Symptom-to-FRU Index