Lenovo ThinkStation 4215 Hardware Maintenance Manual page 70

Hide thumbs Also See for ThinkStation 4215:
Table of Contents

Advertisement

64
Hardware Maintenance Manual
Diagnostic Error Code
014-03X-XXX
014-04X-XXX
Parallel port failure
014-195-XXX
Parallel port Test aborted by user
014-196-XXX
Parallel port test halt, error threshold
exceeded
014-197-XXX
Parallel port test warning
014-198-XXX
Parallel port test aborted
014-199-XXX
Parallel port test failed, cause unknown
014-2XX-XXX
014-3XX-XXX
Parallel port failure
015-000-XXX
USB port Interface Test Passed
015-001-XXX
USB port Presence
015-002-XXX
USB port Timeout
015-015-XXX
USB port External Loopback failure
015-027-XXX
USB port Configuration/Setup error
015-032-XXX
USB port Device Controller failure
FRU/Action
System board
Information only
Restart the test, if necessary.
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility
program," on page 49.
2. Re-run test.
3. Replace the component that is called out
in warning statement.
4. Replace the component under test.
1. If a component is called out, make sure
it is connected and/or enabled.
2. Flash the system and re-test. See
"Updating (flashing) the BIOS" on page
167.
3. Go to "Undetermined problems" on
page 81.
1. Go to "Undetermined problems" on
page 81.
2. Flash the system and re-test. See
"Updating (flashing) the BIOS" on page
167.
3. Replace component under function test.
1. External parallel device
2. System board
No action
1. Remove USB device(s) and re-test.
2. System board
1. Remove USB device(s) and re-test.
2. System board
1. Remove USB device(s) and re-test.
2. System board
1. Flash the system. See "Updating
(flashing) the BIOS" on page 167.
2. System board
System board