66
Hardware Maintenance Manual
Diagnostic Error Code
018-195-XXX
PCI Card Test aborted by user
018-196-XXX
PCI Card test halt, error threshold exceeded
018-197-XXX
PCI Card test warning
018-198-XXX
PCI Card test aborted
018-199-XXX
PCI Card test failed, cause unknown
018-250-XXX
PCI Card Services error
020-000-XXX
PCI Interface Test Passed
020-0XX-XXX
PCI Interface error
020-195-XXX
PCI Test aborted by user
020-196-XXX
PCI test halt, error threshold exceeded
FRU/Action
1. PCI card
2. Information only
Restart the test, if necessary
1. Press F3 to review the log file
2. Restart the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility
program," on page 49.
2. Re-run test.
3. Replace the component that is called out
in warning statement.
4. Replace the component under test.
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, "Using the Setup Utility
program," on page 49.
2. Flash the system and re-test. See
"Updating (flashing) the BIOS" on page
167.
3. Go to "Undetermined problems" on
page 81.
1. Go to "Undetermined problems" on
page 81.
2. Flash the system and re-test. See
"Updating (flashing) the BIOS" on page
167.
3. Replace component under function test.
1. PCI card
2. Riser card, if installed.
3. System board
No action
1. PCI card
2. Riser card, if installed.
3. System board
Information only
Restart the test, if necessary
1. Press F3 to review the log file.
2. Restart the test to reset the log file.