Diagnostic Error Code
020-197-XXX
PCI test warning
020-198-XXX
PCI test aborted
020-199-XXX
PCI test failed, cause unknown
020-262-XXX
PCI system error
025-000-XXX
IDE interface Test Passed
025-00X-XXX
025-01X-XXX
IDE interface failure
025-027-XXX
IDE interface Configuration/Setup error
025-02X-XXX
025-03X-XXX
025-04X-XXX
IDE Interface failure
025-195-XXX
IDE interface Test aborted by user
FRU/Action
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility
program," on page 49.
2. Re-run test.
3. Replace the component that is called out
in warning statement.
4. Replace the component under test.
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, "Using the Setup Utility
program," on page 49.
2. Flash the system and re-test. See
"Updating (flashing) the BIOS" on page
167.
3. Go to "Undetermined problems" on
page 81.
1. Go to "Undetermined problems" on
page 81.
2. Flash the system and re-test. See
"Updating (flashing) the BIOS" on page
167.
3. Replace component under function test.
1. PCI card
2. Riser card, if installed.
3. System board
No action
1. IDE signal cable
2. Check power supply voltages.
3. Reseat IDE signal cable.
4. IDE device
5. System board
1. IDE signal cable
2. Flash the system. See "Updating
(flashing) the BIOS" on page 167.
3. Reseat IDE signal cable.
4. IDE device
5. System board
1. IDE signal cable
2. Check power supply.
3. Reseat IDE signal cable.
4. IDE device
5. System board
Information only
Restart the test, if necessary.