As shown in the below figure, drill a hole on the parrtition or back cabinet for fixing the thermostat fixing plate.
Ø5 hole at two positions
When drilling a hole on the back cabinet, be sure not to damage the cabinet.
2-3
Thermostat
fixing plate
2-4
Close-end connector
insulation tape
Assembly
Return a set of the refrigeration cycle assembly into the outdoor unit base and reassemble sound insulation
3
board, partition plate assembly, fan motor assembly, and back cabinet as original. Fix the thermostat fixing plate to
the back cabinet, built in the inverter assembly, and then connect various cables. After then, incorporate front
cabinet, upper cabinet, wiring cover, and valve cover as before.
In installation work, connect power cord for the cord heater to another breaker separated from one for power cord
4
of the air conditioner.
<RAV-SM560AT-E>
Partition
Thermostat
Fuse
Fuse holder
Cord heater
* Transparent
cover side:
L side
P-shape clamp
Power cord
Perform end process and bundling of each cable.
Using fixing screws (Self-tapping screw type-B Ø3.5 ×
8mm), fix the thermostat to the thermostat fixing plate.
Perform end process for various lead cables and
connect them according to the wiring diagram.
Attach #250 Faston and UL-approved sleeves each to
the end of lead cables which are connected to the
thermostat.
Using insulation tape, apply protective measures to the
connected parts by the close-end connectors.
Using P-shape clamp and the screws (Self-tapping
screw type-B Ø4 × 8mm), fix the power cord to the
thermostat fixing plate.
When the power cord size does not match with P-
shape clamp, procure the most appropriate one at the
local site.