Item
Operation flow and applicable data, etc.
10. Air purifying
This function generates nagative ion while cleaning
control
the air in the room.
If air purifier-ON signal is received while the air
conditioner stops, the air purifier starts operation, and
if it is received while the air conditioner operates, the
air conditioner and the air purifier start operation.
The air ion generator operates linked with the air
purifying operation.
Present status
Stop
Air purifier only
Air conditioner
Joint use of AC and air purifier
Air purifying operation
AC + Air purifying operation
Sending air purifier-ON
1
Air conditioner stops
Operation lamp ON
*1
Memory position
of louver/COOL
*2
Fan ON
Air purifier ON
Air purifying operation
Operation button
PURE button
Air purifier
Stop (All)
AC + Air purifier
AC operation
Louver*1
Cooling position
AUTO, L, L+, M, M+, H
Follows to AC operation
Follows to AC operation
,
2
1
2
Air conditioner operates
Start of air purifier-ON
Air conditioner +
air purifier operate
* When the previous operation was the
operation of air conditioner + air
purifier, an operation of air conditioner
+ air purifier starts by pushing AC
button on the remote controller.
(Operation of air conditioner + air
purifier is stored in memory.)
*1 Swing is available
*2 Fan speed is Fan Auto mode varies
Air conditioner
AC operation*
AC + Air purifier
All stop
All stop
Fan speed *2
Sending air purifier-OFF
3
Air purifier operates
Operation lamp OFF
Fan stop
Air purifier-OFF
Louver close
All stop
– 36 –
Description
in order, (M + 1) → (L) → (L–) →
(SL).
,
3
4
4
Air conditioner +
Air purifier operate
Filter-OFF
Air conditioner operates