Eco Operation; Temporary Operation - Toshiba RAS-M10GKCVP-E Service Manual

Split type
Hide thumbs Also See for RAS-M10GKCVP-E:
Table of Contents

Advertisement

Item
8. ECO
When pressing [ECO] button on the remote controller, a quiet
operation
and mild operation is performed by reducing the fan speed and
the compressor speed.
<Cooling operation>
This function operates the air conditioner with the difference
between the set and the room temperature as shown in the
following figure.
The time correction is performed for 8 minutes each.
(However, the first correction is performed 150 seconds after
start of the operation.)
TA
[˚C]
+4.0
+3.5
+3.0
+2.5
+2.0
+1.5
+1.0
+0.5
TSC
–0.5
–1.0
–2.0
9. Temporary
Pressing [RESET] button starts the temporary operation of
operation
[AUTO] operation. When keeping [RESET] button pressed for 10
seconds or more, the temporary [COOL] operation is performed.
Filter lamp ON
Did you press [RESET] button
for 3 seconds or more?
Did you press [RESET] button
for 10 seconds or more?
Switch to [AUTO RESTART] control.
Operation flow and applicable data, etc.
Zone
Frequency
12
DRY max
11
*12
10
*11
9
*10
8
*9
7
*8
6
COOL min
5
4
3
2
1
0
OFF
* 12 (DRY max - COOL min) /6 x 5 + COOL min
* 11 (DRY max - COOL min) /6 x 4 + COOL min
* 10 (DRY max - COOL min) /6 x 3 + COOL min
* 9 (DRY max - COOL min) /6 x 2 + COOL min
* 8 (DRY max - COOL min) /6 x 1 + COOL min
YES
NO
NO
Temporary [AUTO] operation
YES
YES
NO
Temporary [COOL] Operation
Fan
Time correction
L+ (W7)
+ 1
L (W6)
L– (W5)
± 0
UL (W4)
–1 zone: min 1
Press RESET button.
– 35 –
Description
<Cooling operation>
1) The room temperature (Tao) at
the start time of DRY operation is
detected.
2) According to difference between
the room temperature and the
set temperature (Tsc), the
operation starts with the condi-
tions shown in the left figure.
Set temp.
(Tsc) = Set temp. on remote
controller (Ts) + (0.0 to 1.0)
3) If the room temperature is down
by 2°C or more, turn off the
compressor.
1) When pressing [RESET] button,
the temporary [AUTO] operation
starts.
2) When keeping [RESET] button
pressed for 3 seconds or more,
Pi, Pi, Pi sound is heard and
[AUTO RESTART] control is
changed.
3) When keeping [RESET] button
pressed for 10 seconds or more,
"Pi" sound is heard and the
temporary [COOL] operation
starts.
4) If the filter lamp goes on, press
[RESET] button to go off the filter
lamp, and then press [RESET]
button again.
5) To stop the temporary operation,
press the button again.