Item
Operation flow and applicable data, etc.
12. Air
This function generates nagative ion while cleaning the
purifying
air in the room.
control
If air purifier-ON signal is received while the air condi-
tioner stops, the air purifier starts operation, and if it is
received while the air conditioner operates, the air
conditioner and the air purifier start operation.
The air ion generator operates linked with the air
purifying operation.
Air conditioner stops
OPERATION indicator ON
Memory position
of louver/COOL
Air purifier ON
Air purifying operation
Air purifier operates
OPERATION indicator OFF
Air purifier-OFF
Louver close
Lue lisää nettisivuiltamme: www.ilmalämpöpumput.com
Sending air purifier-ON
,
1
2
1
Air conditioner operates
Start of air purifier-ON
*1
Air conditioner +
air purifier operate
*2
Fan ON
Sending air purifier-OFF
3
,
4
3
Air conditioner +
Air purifier operate
Fan stop
Air conditioner operates
All stop
Present
status
Air purifier only
Air conditioner
Joint use of AC
and air purifier
* When the previous operation was the
operation of air conditioner + air purifier,
an operation of air conditioner + air
purifier starts by pushing AC button on
2
the remote controller.
(Operation of air conditioner + air
purifier is stored in memory.)
Air purifying
operation
AC + Air purifying
operation
*1 Swing is available
*2 Fan speed is Fan Auto mode varies in
order, (M + 1) → (L) → (L–) → (SL).
4
Filter-OFF
– 37 –
Description
Operation button
PURE button
Air conditioner
Stop
Air purifier
AC operation*
Stop (All)
AC + Air purifier
AC + Air purifier
All stop
AC operation
All stop
Louver*1
Fan speed *2
Cooling position
AUTO, L, L+, M,
M+, H
Follows to
AC operation
Follows to
AC operation