Louver Control; Louver Position; Air Direction Adjustment; Swing - Toshiba RAS-M10GKCVP-E Service Manual

Split type
Hide thumbs Also See for RAS-M10GKCVP-E:
Table of Contents

Advertisement

Item

7. Louver control

This function controls the air direction of the indoor unit.
1) Louver
• The position is automatically controlled according to the operation mode.
position
• The set louver position is stored in memory by the microcomputer, and the louver returns to the
stored position when the next operation is performed. (Cooling memory position)
The angle of the louver is indicated as the horizontal angle is 0°.
When the louver closes fully, it directs approx. 49° upward.
<Louver position in cooling operation>
Cooling operation/
AUTO (COOL) / DRY
Initial setting of "Cooling storage position"
Louver : Directs downward (9˚)
Cooling/AUTO
(COOL)/DRY operation

2) Air direction adjustment

Horizontal
blowing

3) Swing

• Swing operation is performed in width 35° with the stop position as
the center.
• If the stop position exceeds either upper or lower limit position,
swing operation is performed in width 35° from the limit which the
stop position exceeded.
Operation flow and applicable data, etc.
Room temp. (Ta) < Set temp. (Tsc) + 3.5
Initial setting of "Cooling storage position"
Louver : Directs downward (9˚)
Powerful
YES
Room temp.
operation
Set temp. +3.5
NO
Cooling memory
position
Air direction
Inclined
Downward
blowing
blowing
Powerful
³
NO
Cooling memory
position
YES
Inclined
blowing
Inclined
Horizontal
blowing
blowing
– 34 –
Description
Louver angle
³
Room temp. (Ta)
Set temp. (Tsc) + 3.5
"Inclined blowing"
Louver : Directs downward (14˚)
NO
³
Room temp.
Set temp. +3.5
YES
• The louver position can
be arbitrarily set up by
pressing [FIX] button.
• Swing
When pressing
[SWING] button during
operation, the louver
starts swinging.
Horizontal
(0˚)