Clean Operation - Toshiba RAS-M10GKCVP-E Service Manual

Split type
Hide thumbs Also See for RAS-M10GKCVP-E:
Table of Contents

Advertisement

Item

13. Clean operation

Unit now performing cooling or dry operation
Only S.CLEAN indicator lights, and clean operation starts
• During clean operations: The louver opens
slightly. The indoor fan operates continuously at
a speed of 260 rpm.
Clean operation times
Cooling: Auto (cooling) Dry
Auto (fan only)
Shutdown
• To stop an ongoing clean operation at any time
Press the start/stop button on the remote controller twice during the clean operation.
(After pressing the button for the first time, press it for the second time without delay
(within 10 minutes).)
Operation flow and applicable data, etc.
Press "STOP" button
Time set now elapses
Operation stops
Operation mode
1. Purpose
The clean operation is to minimize the
growth of mold, bacteria etc. by running
the fan and drying so as to keep the
inside of the air conditioner clean.
Clean operation
When the cooling or dry operation shuts
down, the unit automatically starts the
clean operation which is then performed
for the specified period based on duration
of the operation which was performed
prior to the shutdown, after which the
clean operation stops.
(The clean operation is not performed
after a heating operation.)
2. Operation
1) When the stop signal from the remote
2) The period of the clean operation is
3) After the clean operation has been
Operation time
Up to 10 minutes
From 10 minutes up to 1 hour
1 hour or longer
No clean operation performed
– 39 –
Description
controller is received, the S.CLEAN
indicator (green) on the main body
lights, and the clean operation starts.
(Neither the OPERATION indicator nor
the TIMER indicator light.)
determined by the duration of the
operation performed prior to the
reception of the stop code.
performed for the specified period, the
unit stops operating.
Clean operation time
No clean operation performed
(0 minutes)
2 hours
4 hours

Advertisement