Outdoor Unit (Inverter Assembly) - Toshiba RAS-M10GKCVP-E Service Manual

Split type
Hide thumbs Also See for RAS-M10GKCVP-E:
Table of Contents

Advertisement

8-2. Outdoor Unit (Inverter Assembly)

RAS-3M23GACV-E
A unit P.M.V.
B unit P.M.V.
C unit P.M.V.
Outdoor
fan
motor
Compressor
Outdoor air temp. Sensor
Driver
circuit of
P.M.V.
Current detect
circuit
®
Inverter
Gate drive
(DC
AC)
circuit
Over current
Over current
sensor
detect circuit
Noise filter
Input current
sensor
®
Converter
(AC
DC)
Over current
sensor
®
Inverter
(DC
AC)
Output current
sensor
P.M.V : Pulse motor valve
PWM : Pulse width modulation
Gas side pipe temp. Sensor
M.C.U
• Inverter outdoor frequency control
• A/D converter function
• P.M.V. control
• Discharge temp. control
• Error display
• Signal communication to MCU
• PWM synthesis function
Clock frequency
oscillator circuit
16MHz
Signal communication
to MCU
Clock frequency
oscillator circuit
• PWM synthesis function
10MHz
• Input current release control
• IGBT over current detect control
High power factor
correction circuit
• High power factor correction control
• Signal communication to MCU
• Output current release control
• A/D converter function
Over current
detect circuit
Gate drive
circuit
– 25 –
Discharge temp. Sensor
MCC-818 (SUB-P.C. B)
A unit
send/receive
circuit
B unit
send/receive
circuit
C unit
send/receive
circuit
220–240V
220V
MCC-1438 (MAIN-P.C. B)
M.C.U
IGBT : Insulated gate bipolar
transistor
~
50Hz
~
60Hz

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-m16gkcvp-eRas-m13gkcvp-eRas-3m23gacv-e

Table of Contents