Control Block Diagram - Toshiba RAS-M10GKCVP-E Service Manual

Split type
Hide thumbs Also See for RAS-M10GKCVP-E:
Table of Contents

Advertisement

8-1. Indoor Unit
RAS-M10GKCVP-E, RAS-M13GKCVP-E, RAS-M16GKCVP-E
Heat Exchanger Sensor (Tc)
Room Temperature Sensor (Ta)
Infrared Rays Signal Receiver
and Indication
Initializing Circuit
Clock Frequency
Oscillator Circuit
Power Supply
Circuit
Converter
(D.C circuit)
Noise Filter
From Outdoor Unit
~
220-240V
50Hz
~
220V
60Hz
REMOTE CONTROLLER

8. CONTROL BLOCK DIAGRAM

M.C.U.
Functions
• Cold draft preventing Function
• 3-minute Delay at Restart for Compressor
• Fan Motor Starting Control
• Processing
(Temperature Processing)
• Timer
• Serial Signal Communication
• Clean Function
Serial Signal Transmitter/Receiver
Serial Signal Communication
(Operation Command and Information)
Operation (START/STOP)
Operation Mode Selection
Louver Direction Setting
– 24 –
Indoor Unit Control Unit
Remote Controller
AUTO, COOL, DRY
Thermo. Setting
Fan Speed Selection
ON TIMER Setting
OFF TIMER Setting
Louver AUTO Swing
ECO
Hi-POWER
Air Purifier
SLEEP
Louver
Motor
Louver Motor
Drive Control
Indoor Fan
Motor Control
Indoor
Fan Motor
Air purifier
Micro Switch
Infrared Rays, 36.7kHz
unit

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-m16gkcvp-eRas-m13gkcvp-eRas-3m23gacv-e

Table of Contents