G912I503.WMF
[D]
G912I505.WMF
6. Open the left front cover [A] of the mailbox, and remove the inner plate [B] (! x
3).
7. Install the guide plate bracket [C] (! x 4 - M4x4).
8. Route the cable [D] and clamp it as shown.
9. Connect the cover switch [E] to the cable then install the cover switch (! x 2 -
M4x8).
10. Remove the paper guide plate [F] (! x 2).
SM
CÓPIA NÃO CONTROLADA
BRIDGE UNIT FOR MAILBOX INSTALLATION (G912)
[B]
[F]
[D]
1-29
CÓPIA NÃO CONTROLADA
[C]
[E]
G912I504.WMF