SP2
Mode Number
2975
01
Toner End Time
2976
01
Toner Bottle On Count
2980*
01
Charge Counter
SM
CÓPIA NÃO CONTROLADA
Sets a time limit for issuing the toner near end
warning on the operation panel. The time may
need to be shortened for customers who run
especially large print jobs to ensure earlier
warning of the toner near end condition.
[0 ~ 2,000 / 0 / 10 s step]
0: Normal end detection (90 sheets after near-
end detected – SP2213)
Setting for 1300 s allows about 26 K prints at 5%
coverage starting with a new cartridge, before
the toner near-end warning is issued.
Displays the total ON time of the toner supply
motor, calculated from when the toner bottle was
replaced. Use this to check that the toner end
count when using SP2975 is working properly.
[0 ~ 2,000,000 / 0 / 1 ms Step]
When SP2975 is set to any value other than "0",
this value is displayed when it matches the
setting set for SP2975. When SP2975 is set to
"0", SP2976 is disabled. SP2976 is automatically
set to zero by toner end recovery.
Sets the number of pages to print after toner and
carrier initialization before the charge input is
increased to compensate for deterioration over
time in the polarity of the carrier.
[1 ~ 1,000K / 0 / 1 step]
The strength in the polarity of the carrier in the
toner will eventually decrease and cause lower
charge output. Setting the charge output to
increase after a specified number of prints can
compensate for this effect.
5-19
CÓPIA NÃO CONTROLADA
PRINTER ENGINE SERVICE MODE
Function and [Setting]