Installation Guidelines
Installation Diagram
Air Discharge Swing Baffle
Installation of Outdoor Unit
Install the outdoor unit in a manner to prevent mixing hot
discharged air with return air flow. Also, the unit should be a
suitable distance from obstructions See Figure 1 for mini-
mum installation clearances. Double the dimensions shown if
surroundings are more than 72" tall, or if there is an obstruc-
tion on top. Select the coolest possible place where intake air
temperature is not greater than the outside air temperature
(maximum 113°F). See Table 1, Page 7 for weight of outdoor
unit.
IM 820
IR Receiver and
LED Indicator Lights
Air Discharge Grille
Air Intake Grille
Wireless IR
Remote Control
Air Intake
Air Discharge Nozzle
INDOOR UNIT
Optional Wired
Air Filters
Wall Control
Refrigerant Tubing
and Insulation
Air Intake
OUTDOOR UNIT
Figure 1. Outdoor Unit Minimum Clearances
12"
Min.
Air
Intake
12"
Min.
Air
Intake
40"
Min.
Air
Discharge
20"
Min.
Service
Access
Page 5