Electrical Connection Uk - Miele G 8066 Operating Instructions Manual

Commercial dishwasher
Hide thumbs Also See for G 8066:
Table of Contents

Advertisement

,
All electrical work must be
carried out by a suitably qualified
and competent person in
accordance with local and national
safety regulations.
– Connection should be made via a
suitable isolator, with an on-off switch
which should easily accessible for
servicing work.
– For extra safety it is advisable to
install a residual current device
(RCD) with a trip current of 30 mA (in
accordance with DIN VDE 0664, VDE
0100 Section 739.
WARNING
THIS MACHINE
MUST BE EARTHED
– Equipotential bonding should be
carried out.
– The mains connection cable may
only be replaced by an original Miele
spare part or an appropriate cable
with wire end ferrule.
– For technical data see data plate
and wiring diagram supplied.

Electrical connection UK

The machine must only be operated
with the voltage, frequency and fusing
shown This machine can be converted
in accordance with the conversion
diagram and wiring diagram supplied.
The data plate is located at the back of
the machine and at the bottom of the
wash cabinet behind the service panel
on the left hand side.
The wiring diagram is located behind
the control panel.
The conversion diagram is located
behind the service panel.
See also the installation diagram
supplied.
Bonding connection
There is a screw connection point
marked with the earth symbol (
the back of the machine, to which the
earth lead must be connected.
8
) at
55