The indoor blower will start immediately, and
will run continually until the fan switch is reset
to AUTO.
The continuous indoor blower operation can be
obtained with the thermostat system switch set
in any position, including OFF.
The continuous indoor blower operation is
typically used to circulate the indoor air to
equalize a temperature unbalance due to a sun
load, cooking, or fi replace operation.
To Maintain Your Air Conditioner —
CAUTION:
Be certain the electrical power to
the outdoor unit and the furnace/
air handler is disconnected before
doing the following recommended
maintenance.
1. Regularly:
a. Clean or replace the indoor air fi lter at the
start of each heating and cooling season,
and when an accumulation of dust and dirt
is visible on the air fi lter.
b. Remove any leaves and grass clippings
from the coil in the outdoor unit, being
careful not to damage the aluminum fi ns.
c. Check for any obstruction, such as twigs,
sticks, etc.
2.
Before Each Cooling Season:
If the furnace/air handler blower motor and
the outdoor unit fan motor(s) have oil tubes
at the motor bearings, apply 10 drops of
SAE No. 20 motor oil to each oil tube.
CAUTION:
Do not over-oil, or oil motors not
factory-equipped with oil tubes. The
compressor is hermetically "sealed"
and does not require lubrication.
3.
Before Calling a Service Technician, Be
Certain:
a. The unit thermostat is properly set
— see "To Operate Your Air Conditioner for
Cooling" and "To Operate Your Furnace for
Heating."
b. The unit disconnect fuses are in good
condition, and the electrical power to the
unit is turned on.

1. GENERAL INFORMATION

Read the following instructions completely before
performing the installation.
CAUTION:
This unit uses refrigerant R-410A. DO
NOT under any circumstances use
any other refrigerant besides R-410A
in this unit. Use of another refrigerant
will damage this unit.
Condensing Unit Section — Each condens-
ing unit is shipped with a refrigerant charge
adequate to operate the outdoor section with
an indoor matching coil or air handler, and 15
feet of refrigeration line.
NOTE: DO NOT USE ANY PORTION OF THE
CHARGE FOR PURGING OR LEAK TEST-
ING.
Matching coils and air handlers are shipped with
a small pressurized holding charge to pressurize
them to keep out contaminants. To release the
pressure, read the indoor section installation
instructions carefully.
Liquid and Suction Lines — Refrigerant grade
copper tubing should be used when installing the
system. Refrigerant suction line tubing should
be fully insulated.
Field Connections for Electrical Power
Supply — All wiring must comply with current
provisions of the "National Electrical Code" (ANSI
C1.) and with applicable local codes having
jurisdiction. The minimum size of electrical
conductors and circuit protection must be in
compliance with information listed on the outdoor
unit data label.
3