14 seer r-410a high efficiency split system outdoor air conditioner

Advertisement

Outdoor Air Conditioner
14 SEER R-410A High Efficiency Split System
These units have been designed and tested for
capacity and efficiency in accordance with A.R.I.
Standards. Split System Air Conditioning
units
are designed for use with a wide variety of fossil
fuel furnaces, electric furnaces, air handlers, and
evaporator coil combinations.
These instructions are primarily intended to assist
qualified individuals
experienced
in the proper
installation
of heating
and/or air conditioning
appliances. Some local codes require licensed
installation/service
personnel
for this type of
equipment. Read all instructions carefully before
starting the installation.
USER'S
INFORMATION
Read this owner information to become familiar
with the capabilities
and use of your appliance.
Keep this with literature on other appliances
where you have easy access to it in the future.
If a problem
occurs,
check
the instructions
and follow recommendations
given. If these
suggestions
don't eliminate your problem, call
your servicing contractor.
OPERATING
INSTRUCTIONS
To Operate Your Furnace for
Heating m
1. Set the thermostat system switch to HEAT
or AUTO and the thermostat
fan switch to
AUTO. (See Figure 1)
.
Set the thermostat
temperature
to the
desired temperature
level by pressing the
WARMER or COOLER button. Please refer
to the separate
detailed
user's manual
for complete
thermostat
programming
instructions.The
furnace and indoor blower
will cycle on and off to maintain the indoor
temperature
at the desired heating level.
To Shut Off Your Air Conditioner
Set the thermostat system switch to OFF and the
thermostat
fan switch to AUTO. (See Figure 1)
The system will not operate, regardless of the
thermostat
temperature
setting.
To Operate the Indoor
Blower
Continuously
Set the thermostat
fan switch to ON. (See
Figure 1)
To OperateYour Air Conditioner for
Cooling
1. Set the thermostat system switch to COOL
or AUTO and the thermostat
fan switch to
AUTO. (See Figure 1)
.
Set the thermostat
temperature
to the
desired temperature
level by pressing the
WARMER or COOLER button. Please refer
to the separate detailed thermostat
user's
manual for complete instructions regarding
thermostat programming. The outdoor unit
and indoor blower will both cycle on and
off to maintain the indoor temperature
at
the desired cooling level.
FAN SWITCH
SYSTEM SWITCH
TEMPERATURE
SCALES
TEMPERATURE
SELECTOR
Figure 1. Typical Thermostat

Advertisement

Table of Contents
loading

Summary of Contents for Nordyne 14 SEER

  • Page 1 Outdoor Air Conditioner 14 SEER R-410A High Efficiency Split System These units have been designed and tested for To Operate Your Furnace for capacity and efficiency in accordance with A.R.I. Heating m Standards. Split System Air Conditioning units are designed for use with a wide variety of fossil 1.
  • Page 3: General Information

    The indoor blower will start immediately, unit thermostat is properly will run continually until the fan switch is reset -- see "To Operate Your Air Conditioner for to AUTO. Cooling" and "To Operate Your Furnace for Heating." The continuous indoor blower operation can be b.
  • Page 4: Safety Considerations

    the job site. Ensure coil fins are straight and, if NOTICE: necessary, comb fins to remove flattened and Certain models have external panels fabricated bent fins. from a premium grade of stainlesssteeldesigned Preferred Location of the Outdoor Unit at the to inhibit corrosion.
  • Page 5 6. CONNECTING REFRIGERANT 7. MAKING ELECTRICAL TUBING BETWEEN CONNECTIONS iNDOOR AND OUTDOOR UNiT WARNING: CAUTION: Turn off all electrical power at the main This system utilizes R-410A refrigerant circuit before wiring electrical with POE oil. When servicing, cover power to the outdoor unit. Failure to or seal openings minimize...
  • Page 6: Startup And Checkout

    Maximum Fuse/Circuit Breaker Size-- Circuit Air Filters -- Ensure air filters are clean and in protection for the outdoor unit must be compat- place prior to operating the equipment. ible with the maximum fuse/circuit breaker size Thermostat-- Set the room thermostat function listed on the outdoor unit data label.
  • Page 7: Comfort Alert

    Low-Pressure Switch--(Select M odels) A low- ALERT (Yellow): communicates pressure switchis factory-installed andlocated abnormal system condition through a unique in the suctionline interna! t o the outdoorunit. flash code. The ALERT LED will flash a number Theswitch isdesigned t oprotect thecompressor of times consecutively, pause and then repeat froma lossofcharge.
  • Page 8 circulated by the indoorblowerandverifythat energizes a ftera shortperiodoftime. Feelthe it is coolerthan ambienttemperature. Listen air beingcirculatedby the indoorblowerand for any unusual n oises.If present,locateand verify thatitiswarmer t hanambient temperature. determine the sourceof the noiseandcorrect Listenforanyunusual noises. I f present, l ocate asnecessary.
  • Page 9 StatusLED Status LED Description " Status L ED Troubleshooting Information Green "POWER" Module h aspower Supply v oltage ispresent at module t erminals Red "TRmP" Cornpressor protector isopen Thermostat demand s ignal Outdoor unitpower disconnect isopen Yispresent, butthe Compressor circuitbreaker or fuse(s)is open compressor isnot Broken wireorconnector isnotmaking contact running...
  • Page 10 Determine if both R and C module terminals are Green LED is not on, module does not power up connected. Verify voltage is present at module's R and C terminals. Review 24VAC Power W iring (page 4) for R and C wiring. Determine if R and Y terminals are wired in reverse.
  • Page 11 Refrigerant Charging Charts For Cooling Mode of Operation S4BE-018K "3 Remove refrigerant when above the curve 375" 13" Add refrigerant when below the curve 250" Liquid Temperature S4BE-024K Remove refrigerant when above the curveJ "13 "5 ,,.I refrigerant when below the curve Liquid Temperature (F) *Note: All pressures are listed in psig.
  • Page 12 Refrigerant Charging Charts For Cooling Mode of Operation (Continued) S4BE-030K Remove refrigerant when above the curve "0 0" Add refrigerant when below the curveJ Liquid Temperature (F) S4BE-036K Remove refrigerant when above the curve O" ,--I Add refrigerant when below the curveJ Liquid Temperature (F) *Note: All pressures are listed in psig.
  • Page 13 Refrigerant Charging Charts For Cooling Mode of Operation (Continued) S4BE-042K Remove refrigerant when above the curve I "0 Add refrigerant when below the curveJ Liquid Temperature (F) S4BE-048K Remove refrigerant when above the curve Add refrigerant when below the curveJ Liquid Temperature (F) *Note: All pressures are listed in psig.
  • Page 14 Refrigerant Charging Charts For Cooling Mode of Operation (Continued) S4BE-060K Remove refrigerant when above the curve ,--I Add refrigerant when below the curveJ Liquid Temperature (F) *Note: All pressures are listed in psig. and all temperatures in deg. R...
  • Page 16 iNSTALLER: PLEASE LEAVE THESE iNSTALLATiON iNSTRUCTIONS WiTH THE HOMEOWNER 7086650 Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A. (11/06) 7086650...