INSTALLATION
This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will
continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation.
(Do not cut the ground terminal off under any circumstances.)
IMPORTANT:
If the optional remote control is used, the AA batteries normally installed into the battery holder must be removed. The AA batteries in the
receiver now operate the unit. Having AA batteries in both the battery holder and receiver will damage the gas valve.
GTM remote system Important:
quality AA batteries. The unit will not operate without AA batteries.
36

WIRING DIAGRAM

PROFLAME REMOTE SYSTEM GT/GTM
Profl ame System
Proflame System
Confi guration
Configuration
886 GTMF
886 ON/OFF
Wire Diagram
Illustrated wire diagram
SureFire™ Switch
0.584.907
The AA batteries in the receiver operate the unit. If the batteries become week, they will need to be replaced with
Verify proper operation after servicing.
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can
cause improper and dangerous operation.
Note: 4 AA batteries must be installed to operate
the burner switch.
Do not use a 9 volt battery.
®