Regency HZI234E-NG Owners & Installation Manual page 34

Table of Contents

Advertisement

INSTALLATION
6) Connect the wire harness to the back of the remote receiver; Place wire
clip holder on the side heat shield and put exposed wires into the clip
holder.
7) Place the wire harness under the fi rebox into the wire clip holders
Wire harness
34
Receiver
Wire harness
Wire Clip
Wire Clip
8) Bundle up excess wire harness leaving out the Green (TH) and White
(TH/TP) wires from the Digital fi replace control wire harness, also leave
out the DFC supply wire (black/red).
9) Connect the green wire (TH) to the green (TH) – connect the white (TH/
TP) to white TH/TP) and fi nally connect the red/black DFC supply to the
red/black DC supply wire.
The Remote receiver will now power the digital fi replace control board.
10) Install batteries into the remote receiver, program handheld to receiver
following the installation instructions provided, and then install the small
remote receiver cover plate.
11) Program remote as per Profl ame remote manual.
12) Reinstall faceplate.
DFC - DC supply
connection
TH/TP
Remote
Receiver
Cover Plate
®
Regency
HZI234E Direct Vent Gas Insert
TH

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hzi234e-lp

Table of Contents