3.22 Log Utilities

3.22
Log Utilities
3.22.1 Function Description
This function logs error information generated while a test is in progress and stores the results
in RAM. This function can store data on a floppy disk, or output the data to a printer or the
display.
The error information is displayed in the following order:
1. Error count (CNT)
2. Test name, Subtest number (TS-No)
3. Pass count (PASS)
4. Error status (STS)
5. FDD/HDD or memory address (ADDR)
6. Write data (WD)
7. Read data (RD)
8. HDC status (HSTS)
9. Error status name (ERROR STATUS NAME)
If the power switch is turned off, the error information will be lost.