S1 Dream Espresso Machine – GUI Addendum

7.9.1 Set Coffee Water Temperature

See also the Offset setting which is one of the last menu settings described later in this
document. Since Offset works in conjunction with this setting, you could have the coffee
temperature below boiling but have the offset incorrectly set to a positive value that causes
the water temperature to be too high.

7.9.2 Set Steam Boiler Temperature/Pressure

Dream GUI Addendum
Starting from the last menu in the previous section,
press the Down arrow to highlight the Coffee
Temperature icon and display COFFEE TEMPERAT
on the top of the screen. Then press the Menu button
to enter the Coffee temperature (group boiler)
programming screen.
Use the up or down arrows to increase or decrease the indicated
temperature until the desired espresso temperature is showing.
Then press the Menu button to lock in this value and return to the main
Profile menu.
If B.English or Italian are selected as the language this value is show in
Celsius.
Range: 185-257F
or 85C-125C
In spite of upper range please keep actual value below boiling.
Not that the higher you altitude the lower the boiling point of water.
Depending on where you are in the profile menus,
press the Up or Down arrow to highlight the Boiler
Temperature icon and display BOILER TEMPEARAT
on the top of the screen. Then press the Menu button
to enter the boiler temperature (steam boiler)
programming screen.
Use the up or down arrows to increase or decrease the indicated
temperature until the desired steam temperature is showing. Note that
unlike the coffee temperature, you are aiming for a temperature here that
produces the desired steam boiler pressure as indicated by the
manometer on the front panel behind the group.
The normal usage range is 1.0-1.5 bar. The 254F value shown
produces about 1.3bar which is what the earlier generations of S1 are
permanently set to. The range of available values is 239-262F or 115-
123C. The lower values prevents you from select too weak a steam
value and the upper value prevents boiler overpressure.
Then press the Menu button to lock in this value and return to the main
Profile menu.