Install memory modules according to the installation conditions.
2
Start the BIOS Setup Utility.
3
Select the [Memory] menu, [Configure System RAS and Performance], and
then press the [Enter] key.
4
Select [Desired Memory Configuration], and press the [Enter] key. Select
[RAID], and press the [Enter] key.
5
Select [View Configuration Detail] and press the [Enter] key.
The View Configuration Detail submenu window appears.
6
Check that [Configuration Possible] and [Hot Replace] are set to [Yes].
If [No] is displayed, the memory modules were not installed correctly. Install them correctly
according to the installation conditions.
If [Hot Replace] is set to [No], the memory modules cannot be replaced while the server
is running.
7
Press the [F10] key.
A confirmation message appears, asking whether you want to save the changed BIOS settings.
8
Select [Yes] and press the [Enter] key.
The memory RAID function is enabled after the system is restarted.
Spare Memory Function
Assign spare memory modules by memory board. The available capacity (logical capacity) of the
memory is the half of that of the physical memory.
Installation Conditions
Install the memory according to the following conditions.
Table: Conditions for the Spare Memory Function
Memory Board A
Bank 1
Bank 2
1A
1B
2A
2B
: Memory installed
-: Memory not installed
Memory Board B
Memory Board C
Bank 1
Bank 2
Bank 1
1A
1B
2A
2B
1A
-
-
-
-
-
-
PRIMERGY RX600 S2 User's Guide
Memory Board D
Bank 2
Bank 1
1B
2A
2B
1A
1B
-
-
-
-
-
-
-
-
-
-
1
2
3
4
5
6
7
8
Bank 2
2A
2B
-
-
-
-
9
195

Advertisement

Table of Contents
loading

Table of Contents