Notes On Advanced Uninterruptible Power Supply (Ups) - Fujitsu Primergy RX600 S2 User Manual

Hide thumbs Also See for Primergy RX600 S2:
Table of Contents

Advertisement

You cannot change the drive letters for the system and boot drive.
■ For Windows Server 2003
1
Click [Start] → [Administrative Tools] → [Computer Management].
2
Click [Disk Management].
3
Right-click the partition to change the letter and click [Change Drive Letter and
Path].
The [Change Drive Letter and Path] window appears.
4
Click [Edit].
The [Change Drive Letter or Path] window appears.
5
Change the drive letter.
■ For Windows 2000 Server
1
Right-click [My Computer] icon on the desktop and select [Manage].
2
Click [Disk Management].
3
Right-click the partition to change the letter and select [Change Drive Letter
and Path].
The [Change Drive Letter and Path] window appears.
4
Click [Edit].
The [Change Drive Letter or Path] window appears.
5
Change the drive letter.
5.5.4 Notes on Advanced Uninterruptible Power Supply
(UPS)
Note the following points when using an advanced uninterruptible power supply (referred to as UPS
afterward).
■ UPS Shutdown Time Setting
Specify enough time for the UPS power-off time (time from the shutdown direction to the actual power-
off). If this time is set insufficiently, the power will be cut off before system shutdown, which may result
in destruction of data. For more details, refer to the manuals for UPS and UPS management software.