Figure 36. The Control Center Calibration Window; Calibrate The Sensor - Ioline SmarTrac I/S Series User Manual

Table of Contents

Advertisement

2.
Insert the tool that is used during registration into the tool
jaw on the carriage. If calibrating for the Ioline blade holder,
insert the registration tool (Ioline PN 105745) included in the
Accessory Kit.
3.
Move the carriage and material so that the tip of the tool is near
the lower left corner of the black square.
4.
Turn the Speed knob down to the minimum level and continue
to position the carriage and material until the tip is exactly over
the corner. Gently press the tool down onto the paper to ensure
that the tip is lined up. See the Figure 35.
5.
Press the Set Origin button on the keypad and ensure that the
keypad light is Green.

Calibrate the Sensor

1.
Open the Ioline Control Center. A shortcut is available in
Start>Ioline.

Figure 36. The Control Center Calibration window.

2.
In the Menu Bar, choose Calibrate>Calibrate Plotter...
(Figure 36.)
3.
Press the Sensor Calibration button at the bottom of the window.
4.
Ensure the cutter is ready with the tip of the tool positioned
over the lower left corner of the black box and a Green keypad
LED. Press the Calibrate Sensor button in the small window
that appears. (Figure 37.)
5.
The sensor will automatically perform the calibration process
and update the four values in the windows.
6.
Press Done when the process is complete.
Chapter 5: Routine Maintenance
53