Ioline SmarTrac User Guide
Hint
Sensor calibration is required
if using any tool other than the
Ioline blade holder (i.e. a ball
point pen). Calibration is also
required to switch back to the
Ioline blade holder after calibrat-
ing for a different tool.
Calibrating the Sensor for
Contour Cutting
The registration sen-
sor is calibrated for
the standard Ioline
cutting tool at the
factory before ship-
ment. If the registra-
tion sensor if ever
replaced or if tools
other than the stan-
dard Ioline blade
holder are used for
registration, use the
following process
Figure 33. Print and measure a 1-cm black square
to recalibrate the
on a white background.
sensor:
Prepare to
Calibrate the
Sensor
1.
Print a black
1-cm square on
a white back-
ground. Use the
sensor calibra-
tion files, 1cm_
square.jpg or
Figure 34. Registration tool in jaw.
1cm_square.doc,
in C:\Ioline\
Calibration to
generate the
square. Make
sure that there
is at least a mar-
gin of 3 inches
from each edge
of the material
to the edges of
the box. Print-
ing the square
in the center of
a standard sheet
of white paper
is acceptable.
Make sure to
carefully mea-
sure the square
after printing to
ensure that it is
exactly 1-cm.
Figure 35. Press the tool down to verify the tip lines
up with the corner of the box.
1-cm