3.
Precisely measure both X-axis and Y-axis lines. Better accuracy
in measurement equals better calibration.
4.
Measure both sides and the top and bottom of the box.
X1
~40 in.
Figure 32. The Calibration Box and measurements.
5.
Take the average of the horizontal (Y) values by adding them
together and dividing by 2. Repeat this procedure for the verti-
cal (X) values.
Example:
If X1 = 39.750 in. and X2 = 39.700 in.
The sum is 79.450 in. (39.750 in. + 39.700 in. = 79.450 in.).
The average is 39.725 in. (79.450 in. / 2 = 39.725 in.)
The X calibration value is the average, 39.725 in.

Enter the Calibration Data:

1.
Enter the measured values in the boxes in the Calibration win-
dow. Make sure the SmarTrac is in START mode (green LED).
Select the Set Calibration button.
2.
The cutter will send the calibration values and the new Cali-
bration Setting will be displayed in the boxes in the win-
dow.
3.
Click on Done when finished.
Y1
X2
Y2
Chapter 5: Routine Maintenance