Top Vent, Wall Mounted Graph, H*42Df-St; Top Vent, Wall Mounted Termination (One Elbow); Top Vent, Wall Mounted Termination (Multi Elbow) - Montigo H42DF ST Installation & Maintenance Manual

Indoor residential gas fireplace
Table of Contents

Advertisement

H*42DF ST Indoor Gas Fireplace
Section 3-3-1:
VENTING LAYOUT: Wall mounted termination.
Selection of components and details of venting layout should
adhere to the following guidelines:
Vent terminations must not be recessed in walls or siding.
For Heat Shield requirements see Section 3-3-3 on page 15.
Once the proposed venting layout has been determined refer to
Figure 11 or 12 to ensure the layout is acceptable.
Notes Wall Mounted Terminations: TOP VENT
All measurements for vertical or horizontal runs are measured
from center of the vent pipe.
Venting runs must fall within the limits set by the venting graph,
see Figure 11.
The Venting Graph
Measure the vertical height from the fireplace hearth to the centre of the
termination and the horizontal run from the fireplace flue collar to the wall
flange of the termination. Plot on the Venting Graph Figure 11 with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the
installation is acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 120" and the horizontal
run to the wall flange of the vent termination is 138", this would be
an acceptable installation.
Example B: (Unacceptable Installation)
If the vertical dimension from the hearth is 48" and the horizontal
run to the wall flange of the vent termination is 96", this would
NOT be an acceptable installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 72" and
the horizontal run to the wall flange of the vent termination is 120",
this would NOT be an acceptable installation.
Acceptable vent run
within non-shaded area.
B
50"
12" LP
36" NG
Figure 11. HL42DF*-ST Top Vent Venting Graph for wall mounted terminations.
Page 12
Installation
A
C
Unacceptable vent run
within shaded area.
If your isnstallation does not fall
within the venting parameters,
please contact local Montigo dealer
for Power Venting options.
Flex or Rigid
Insulated Sleeve
CRS101
Hearth
Figure 11a. Top Vented, wall mounted installation with one 90° bend. The vent
run must comply with Venting Graph for Top vent, wall mounted terminations,
Figure 11.
150" MAX
Figure 11b. Top Vented, wall mounted Multi-elbow installation. See Venting
Graph for Top vent, wall mounted terminations, Figure 11.
Figure 11c. Top Vented, wall mounted Retracted Multi-elbow installation. See
Venting Graph for Top vent, wall mounted terminations, Figure 11.
36" MAX NG
12" MAX LP
Heat Shield
Termination
Exterior
Wall
Heat
Shield
Termination
Solid Section
Flex Section
Exterior
ll
Wa
Hearth
30" MAX
Heat
Shield
126"
Solid Sectio
Termination
Flex Section
Exterior
Wa
Hearth
XG0237 - 120611.1
50"
.
ll