Rear Vent, Wall Mounted Termination (45° Corner) - Montigo H34DL Installation & Maintenance Manual

Indoor residential gas fireplace
Hide thumbs Also See for H34DL:
Table of Contents

Advertisement

45° Corner Installation.
Attach an EEL-45 / PEL-45 (45° elbow) directly onto the flue collar.
Cut the MXT-20 / PXT-20 to suit, and attach it to the EEL-45 / PEL-
45. Slide the fireplace into position and attach to the termination.
Figure 19. Corner installation. (NG Models Only)
45° or less Corner Installation.
Use an MTO-4 / PTO-4 termination and an MFL-1 / PFL-1 or MFL-2
/ PFL-2 (12" or 24" compressed length) and a frame, if appropriate.
Flex may be turned to obtain desired degree of angle required but
must not exceed 45°.
Figure 19a. Flex installation. (NG Models Only)
Note: Through the wall venting kits are also available for both
the Straight and the Corner Installation. The Kit includes a heat
shield, a MFL-1 (f/f) / PFL-1 (f/f) flexible pipe, and a termination with
or without a mounting frame.
XG0140 - 120611.1
Installation
100 or 101
Rigid Section
Rigid Elbow
100 or 101
Flex Section
H-Series DL Gas Fireplace
Page 15