9. Type the following command to run the second configuration utility:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The HMC is configured to load the adapter device driver upon reboot. Reboot the HMC
|
PC.
70
pSeries 690 Installation Guide
11) 88
12) 96
13) 104
14) 112
15) 120
16) 128
Board #1 How many ports? (1–16)
Answer: Count the total number of Enhanced RANs you are attaching to the
128-Port ASYNC adapter and multiply by two. For example: 2 (RANs) multiplied
by 2 equals 4. Enter the selection number 4), for 32 in this example, at the
prompt.
d. Question: Do you want to set Altpin on this board? ('y' or 'n')
Answer: No
If two 128-Port ASYNC adapters are installed in the system, the utility repeats
the previous sequence of questions for each.
/usr/sbin/cxconf. The configuration utility will guide you through a series of
questions. The term C/CON is synonymous with Enhanced RAN or RAN:
a. Question: How many C/X cards do you have?
Answer: Enter the total number of 128 Port ASYNC adapters installed in the
HMC PC.
b. Question: How many C/CONs (RANs) are connected to card 1 line 1?
Answer: Enter the total number of RANs on line 1. For this example, two
concentrators (RANs) are connected to line 1.
c. Question: What type of wiring scheme are you going to use for card 1, line 1?
A) 8 Wire Direct
B) 4 Wire Direct
C) RS422 Sync
D) RS232 Sync
Answer: A
d. Enter the type of communication mode to use on line 1.
(Type L for a list) [14]
Answer: 14
e. Question: How many ports does this C/CON (RAN) support? (conc #1)
Note: The maximum number of ports here is 16. [16]
Answer: 16
f. Question: How many C/CONs (RANs) are connected to card 1, line 2?
Answer: Enter the number of RANs connected to line 2. If RANs are connected
to Line 2, return to 9c above, and repeat the previous steps for line 2.