Restriction in High Side of System.
V isually Check for Frost Spot to Locate
Restriction. Repair as Necessary.
I
Evacuate & Charge
I
System
(O.K.)
RUNS CONTINUOUSLY
WITHIN LIMITS
Disconnect Blow er W ire a n d Check For
Cycling O ff at 138-193 kPa (20-28 PSD
PRESSURE FALLS
BELOW 20 PSI
Defective Pressure
S w itch
I
Replace. *Do N ot Discharge
System. There is a Schrader
Valve in the Fitting
I
System
(O.K.)
AMBIENT TEMP.
A/C
PICK-UP
OUTLET
TEMP.
SUBURBAN
OUTLET TEMPERATURE
W ITHIN LIMITS
System
(O.K.)
MISSING
T
Install Expansion Tube
i
Evacuate & Charge
System
(O.K.)
SERVICE DIAGNOSTIC PROCEDURE
INSUFFICIENT COOLING — A/C SYSTEM S W ITH CYCLING CLUTCH — EXPANSION TUBE
MOVE TEMP. LEVER RAPIDLY BACK AND FORTH
FROM HOT TO COLD. LISTEN FOR DOOR HITTING
This System Does Not Have a Sight Glass. U nder No
C ircum stances Should a Sight Glass Be Installed
Feel Liquid Line Before Expansion Tube
INLET PIPE AND OUTLET
PIPE SAME TEMPERA
TURE OR OUTLET
COLDER THAN INLET
Install Gage Set and Check Com pressor
Cycling Press,
i
ON at 282.6-351.6 kPa [41-51 PSD
OFF at 138-193 kPa (20-28 PSD
CYCLES WITHIN LIMITS
CYCLES OFF AT 138-193
kPa (20-28 PSI) OR DOES
NOT PULL DOWN TO
PRESS
Install Therm om eter in A C O utlet and
Check Performance
1. SET TEMP. LEVER TO FULL COLD
2 SET SELECTOR LEVER TO MAX AC
3. SET BLOWER SWITCH ON HI
4 CLOSE DOORS AND WINDOWS
5. RUN ENGINE AT 2000 R.P M
6. USE AUX. FAN IN FRONT OF GRILL
21°C
27° C
32° C
38° C
(70° F)
(80°F)
(90°F)
(100° F)
5-8°C
5-8°C
6-10°C
6-1 f C
(41-47)
(41-47)
(42-50)
(43-57)
6-9°C
6-9°C
10-14°C
12-17°C
(42-48)
(42-48)
(50-58)
(54-62)
OUTLET TEMPERATURE
HIGH AS PER CHART
Check Com pressor Cycling
ON CONTINUOUSLY
* ' Discharge System and Check For
M issing Expansion Tube
Repair or Replace Screen
I
Evacuate & Charge
System
(O K )
C hart 1 B-3--Pressure C ycling CCOT System D iagnosis
(PRESSURE SENSING)
AT EACH END
Feel Evaporator Inlet and Outlet Pipes
CYCLES HIGH OR LOW
-------- r - -------
OR OFF BELOW 20 PSD
43 °C
(11 0F)
6-1 f C
(43-51)
14-19°C
(57-67)
IN PLACE
T
Check Com pressor Inlet
Screen
_____ I _ _____
System Over Charged
I
Evacuate & Charge
I
System
(O.K.)
AIR C O N D ITIO N IN G
(ON ABOVE 51 PSI
Defective
Pressure
Switch
i
Replace
*Do Not Discharge
System, There
Is a Schrader
System
(O K )
CYCLE ON AND OFF OR
REMAINS OFF FOR LONG
PERIOD OF TIME
I
Discharge System and
Check for Plugged Expansion Tube
i
Replace
i
Evacuate & Charge
System
(O.K.)
LIG H T TRUCK S E R V IC E MANUAL
1B-13