Chapter 4— Troubleshooting and Maintaining the Terminal

Problems Transmitting Data Through the Intermec Gateway or DCS 30X

Problems Transmitting Data Through the Intermec Gateway or DCS 30X
Problem
Transaction Buffer Full.
Sending Buffer Transactions.
Transaction Aborted.
Transmit Error XX, press Enter.
Receive Error XX, press Enter.
Shutting down.
Controller Shutdown.

Problems Scanning Bar Code Labels

Problems Scanning Bar Code Labels
Problem
The terminal is turned off.
The input device connected to the terminal does
not appear to work well or read bar code labels
very quickly.
76
If you have a problem while running the application on the terminal in a
UDP Plus or WTP network, check these possible communications
problems.
Possible Solution
The buffer holding transactions to be sent to the Intermec Gateway or DCS 30X
is full. Stop collecting data with this terminal. Make sure the terminal is
communicating with the Intermec Gateway or DCS 30X and let the terminal send
all the transactions in the buffer before you continue collecting data.
This is an information message to tell you that buffered transactions are now being
sent to the Intermec Gateway or DCS 30X. You can begin collecting data again
once the message clears.
The transaction just sent to the Intermec Gateway or DCS 30X was not received.
Try sending the transaction again.
There is an error transmitting data to the Intermec Gateway or DCS 30X. XX
represents the status code error. Note the error code listed in the message and
contact your local Intermec service representative for help. Press the Enter key to
continue.
There is an error receiving data from the Intermec Gateway or DCS 30X. XX
represents the status code error. Note the error code listed in the message and
contact your local Intermec service representative for help. Press the Enter key to
continue.
The Intermec Gateway or DCS 30X is shutting down. You may continue
collecting data and buffer the transactions in the terminal until the Intermec
Gateway or DCS 30X starts again or stop collecting data with the terminal.
The Intermec Gateway or DCS 30X has shut down. You may continue collecting
data and buffer the transactions in the terminal until the Intermec Gateway or
DCS 30X starts again or stop collecting data with the terminal.
If you cannot scan bar code labels or you are having problems with the
scanner, check these possible problems.
Possible Solution
Make sure the terminal is turned on. Press f or ' to turn on
the terminal.
Make sure that the Scanner Selection command is set to the
specific tethered scanner you have attached. For help, see
"Scanner Selection" in Chapter 6, "Configuration Command
Reference," in the 2400 Family system manual.
Check the bar code symbologies you have enabled on the
terminal. Enable only the symbologies that you are using.