JRC JMA-2353 Instruction Manual page 96

Table of Contents

Advertisement

Chapter 2 OPERATIONS
2.7 SOFT KEY OPERATION
Reference:
Options of the transmitter pulse length vary depending on the range.
For details, see "7.2 SCANNER".
Soft key 2: Not available
Soft key 3: Not available
Soft key 4: Not available
 Effects of transmitter pulse length
 SP :
The transmitter pulse length becomes shorter, and the range resolution improves.
The effect of suppressing sea clutter returns and rain/snow clutter returns heightens.
Recommended condition for selection:
In bays / harbors where targets are densely crowded
Rough sea state due to torrential rain or stormy weather
 MP :
The normal transmitter pulse length is set.
Both range resolution and sensitivity are appropriately set.
Recommended condition for selection:
General navigation
 LP :
The transmitter pulse length becomes longer, and sensitivity improves.
Small targets are zoomed and are easy to observe.
When the sea state is bad, detection performance decreases.
Recommended condition for selection:
Detection of small targets in good weather conditions
Usable transmitter pulse length varies according to the type of scanner unit being used
and the observation range being used. For usable pulse length, see the section
"SCANNER" in "SPECIFICATIONS".