Facing Requirements; Face Dimensions - Travis Industries 21 DV RV User Manual

Hide thumbs Also See for 21 DV RV:
Table of Contents

Advertisement

24
Installation (for qualified installers only)

Facing Requirements

NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it
does, it is considered a mantel and must meet the mantel requirements listed in this manual.

Face Dimensions

Face
Arched Faces
Bungalow, T of L 35-3/8"
Victorian Lace
Looking Glass
Wilmington
Facing Under 1" Thick
Any material that protrudes
more than 3/4" in front of the
facing is considered a mantel
and must meet the mantel
requirements in this manual.
NOTE: The facing tucks
behind the flanges.
Recommended Order of Installation We
recommend installing the facing (drywall, tile)
under the notch at the front of the fireplace
("a") - then install the sides and top ("b" and
"c")
Facing Over 1" Thick
Facing that protrudes in front of the face above the face (or within 1/2" of each side) must be
made of non-combustible materials.
NOTE A 3/8" gap above the face is required for face installation and removal.
© Travis Industries
Height
Width
Bottom of Face
35-1/2"
21-1/8"
Flush w base of fireplace
21-1/8"
Flush w base of fireplace
35-1/2"
21-1/8"
Flush w base of fireplace
36-3/4"
23-1/2"
1-1/4" BELOW base of fireplace
36-3/4"
22-1/8"
1-1/4" BELOW base of fireplace
b
4-3/4"
3-3/8"
30-1/4"
(approx.)
a
NOTE The facing tucks under the notch at the front
of the fireplace (3/8" above the base of the fireplace).
4060517
Installation Notes
Arched top is 25-3/4" radius
Cast face is approx. 2" thick
The facing (combustible
or non-combustible)
must maintain a 1/2"
clearance to the sides
and top of the fireplace.
c
100-01158