Installation Guide
New Auxiliary Output Menu.
The auxiliary output menu allows the installer to choose the output on a desired wire
from the main unit. This option will allow for such things as custom remote features,
additional remote starter accessories and button configurations.
Enter menu 5 By pressing button 5, located to the left of the
Setting 1 - Output 1 - Yellow wire on the 14-pin connector
1 Ground On Start
2 Park Light (Negative)
3 Re-arm
Press the Program Switch 1 time to select setting 1 (This will be confirmed by 1 LED flash and one park light flash)
Press and hold the Program Switch until you receive the appropriate # of park light flashes and/or horn honks.
Release. Press the Program button momentarily to move to next program step or repeat to change selection.
Setting 2 - Output 2 - Brown wire on the 14-pin connector
1 Dome Light Supervision
2 Second Lock Output
3 Disarm
Press the Program Switch 2 times to select setting 2 (This will be confirmed by 2 LED flashes and 2 horn honks)
Press and hold the Program Switch until you receive the appropriate # of park light flashes and/or horn honks.
Release. Press the Program button momentarily to move to next program step or repeat to change selection.
Setting 3 - Output 3 - Red/White wire on the 14-pin connector
1 Dome Light Supervision
2 Second Lock Output
3 Trunk Release
Press the Program Switch 3 times to select setting 3 (This will be confirmed by 3 LED flashes and 3 horn honks)
Press and hold the Program Switch until you receive the appropriate # of park light flashes and/or horn honks.
Release. Press the Program button momentarily to move to next program step or repeat to change selection.
Setting 4 - Output 4 - Orange wire 0n the 14-pin connector
1 Park Light (Negative)
2 Dome Light Supervision(Button 5)
3 Latched Output (Button 5)
4 60 Second Output(Button 5)
5 Momentary Output (Button 5)
Press the Program Switch 4 times to select setting 4 (This will be confirmed by 4 LED flashes and 4 horn honks)
Press and hold the Program Switch until you receive the appropriate # of park light flashes and/or horn honks.
Release. Press the Program button momentarily to move to next program step or repeat to change selection.
Note: Setting 6 in the Starter Settings menu must be programmed for option 2 (Auxiliary Output) before this menu will
operate as an Auxiliary output.
Setting 5 - Output 5 - Yellow wire on the 2-pin white connector
1 Momentary Output (Button 6)
2 60 Second Output (Button 6)
3 Latched Output (Button 6)
4 Ground On Start
5 Park Light (Negative)
Press the Program Switch 5 times to select setting 5 (This will be confirmed by 5 LED flashes and 5 horn honks)
Press and hold the Program Switch until you receive the appropriate # of park light flashes and/or horn honks.
Release. Press the Program button momentarily to move to next program step or repeat to change selection.
Menu 5 - Auxiliary Output Settings
1 Flash
Ground output During crank ( Bulb test/ Caravan 2nd Starter...)
2 Flashes
Negative output upon park light activation
3 Flashes
See starter settings options, Setting 3
1 Flash
30 second output on unlock
2 Flashes
Press Unlock twice within 3 seconds ( Window Roll-up...)
3 Flashes
.75 Second pulse on Unlock and start
1 Flash
30 second output on unlock
2 Flashes
Press Unlock twice within 3 seconds ( Window Roll-up...)
3 Flashes
Output for .75 seconds or until the button is released
1 Flash
Negative output upon park light activation
2 Flashes
30 second output on unlock
3 Flashes
Activated on first button press, deactivates on second press.
4 Flashes
Output will activate for 60 seconds when button 5 is pressed.
5 Flashes
Output will activate for .75 seconds when button 5 is pressed
1 Flash
Output will activate for .75 seconds when button 5 is pressed
2 Flashes
Output will activate for 60 seconds when button 5 is pressed.
3 Flashes
Activated on first button press, deactivates on second press. (Button 5)
4 Flashes
Ground output During crank ( Bulb test/ Caravan 2nd Starter...)
5 Flashes
Negative output upon park light activation
# &
*
buttons.