Output Bin Tests; Output Bin Test-Standard Bin; Output Bin Feed Test - Lexmark Infoprint 1332 User Manual

Table of Contents

Advertisement

Output Bin Tests

Output Bin Test—Standard Bin
This test is used to verify if the standard bin sensor is working correctly.
To run the Standard Bin Sensor Test:
1.
Select Output Bin Tests from the Diagnostic menu.
2.
Select Output Bin Tests - Sensor Tests.
3.
Select Sensor Tests - Standard Bin. "Standard Bin/Full=CL" message displays.
Manually actuate the bin sensor by moving the flag in and out of the sensor. The display
indicates OP (open) when the flag is out of the sensor and CL (closed) when the flag is in the
sensor.
4.
Press Return/Stop to exit the test.

Output Bin Feed Test

Note: If the Configure Bins printer setting is link rather than mailbox, the printer selects its own
internal bin linking regardless of which output bin is selected for the feed test
This test is used to verify that media can be fed to a specific output bin. No information is printed on
the media fed to the output bin because the printhead is not turned on during this test. This test can
be run from any input source and will support any size paper or envelope supported by the printer.
To run the Output Bin Feed Test:
1.
Select Feed Test from the Output Bin Test menu.
2.
Select the output bin you want the paper to exit into. The standard bin as well as any output
option bin installed on the printer is shown on the menu. (The output bin displayed is in the order
installed on the printer.)
3.
Select either Single (one sheet of media feeds to the selected output bin) or Continuous
(media continues feeding to the selected output bin) until Return/Stop is pressed.
4.
Press Return/Stop to exit the test.
Infoprint 1332/1352/1372
3-11
Diagnostic aids

Advertisement

Table of Contents
loading

This manual is also suitable for:

Infoprint 1352Infoprint 1372

Table of Contents