BELL_CORE_PATTERN4_TIMING

Value Format
Description
Value Range
Default Value
BELL_CORE_PATTERN5_TIMING
Value Format
Description
Value Range
Default Value
5.5.6 Flexible Button Settings
FLEX_BUTTON_FACILITY_ACT
Value Format
Description
Value Range
Default Value
Web User Interface Reference
FLEX_BUTTON_FACILITY_ARG
Value Format
Document Version 2014-04
Comma-separated Integer
Specifies the cadence, in milliseconds, of pattern ID 4, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using up to 8 whole numbers (on 1, off 1, on 2, off 2...) separated by
commas.
0–5000 (0: Infinite time)
Note
Avoid setting 1–50 for any of the values.
300,200,1000,200,300,4000
Integer
Specifies the cadence, in milliseconds, of pattern ID 5, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using up to 8 whole numbers (on 1, off 1, on 2, off 2...) separated by
commas.
0–5000 (0: Infinite time)
Note
Avoid setting 1–50 for any of the values.
500
Integer
Specifies a particular Facility Action for the flexible button. No facility
action will be taken for the button if the string is empty or invalid.
0–2
0: Empty
1: ONETOUCH
2: BLF
0