Cfg_Master_File_Path - Panasonic KX-UTG200 Administrator's Manual

Hide thumbs Also See for KX-UTG200:
Table of Contents

Advertisement

5.3.6 Provisioning Settings
Description
Value Range
Default Value

CFG_MASTER_FILE_PATH

Value Format
Description
214
Administrator Guide
Specifies the URL of the product configuration file, which is used when
all units with the same model number need the same settings.
Note
When you change this setting, set "PROVISION_ENABLE" to
"Y" at the same time.
Max. 1024 characters
Note
The format must be RFC 1738 compliant, as follows:
"<scheme>://<user>:<password>@<host>:<port>/<url-path>"
"<user>" must be less than 127 characters.
"<password>" must be less than 127 characters.
"<user>:<password>@" may be empty.
":<port>" can be omitted if you do not need to specify the
port number.
If "{mac}" is included in this URL, it will be replaced with the
unit's MAC address in lower-case.
If "{MAC}" is included in this URL, it will be replaced with the
unit's MAC address in upper-case.
If "{MODEL}" is included in this URL, it will be replaced with the
unit's model name.
If "{fwver}" is included in this URL, it will be replaced with the
unit's firmware version.
If this URL ends with "/" (slash), "{MODEL}.cfg" is automatically
added at the end of the URL.
For example, CFG_PRODUCT_FILE_PATH="http://host/
dir/" becomes CFG_PRODUCT_FILE_PATH="http://
host/dir/{MODEL}.cfg".
Empty string
Note
The URL specified by your phone system dealer may be preset
in the unit.
String
Specifies the URL of the master configuration file, which is used when
all units need the same settings.
Note
When you change this setting, set "PROVISION_ENABLE" to
"Y" at the same time.
Document Version 2014-04

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Kx-utg300

Table of Contents