6. HOW TO COMMUNICATE WITH ID TAGS
6 - 52
Normal completion
X4
CH1 ID
instruction
complete
Abnormal completion
X5
CH1 error
detection
<Read stored data
U0\
BMOV
G100
D1091
K2
Number of writes
calculation result
during Control
Number of Writes
<Sort upper, middle, and lower bytes >
DROL
D1091
K8
Number of writes
calculation result
during Control
number of Writes
SET
M1092
Control
Number of
Writes
normal
completion
<Read error details storage area
U0\
MOV
G41
D1090
Error details
during Contro
Number of
Writes
SET
M1093
Module error
during Contro
Number of
Writes
END
6 - 52
>
>