Step
Check
5
Perform a print test.
Does the error remain?
6
Perform a print test.
Does the error remain?

282.00 Sensor (finisher media entrance) late jam

Step
Check
1
Check the bridge unit media transport rolls.
Are the bridge unit media transport rolls free of excess
wear and contamination?
2
Check sensor (bridge unit media exit) for proper
operation.
1. Enter the Diagnostics Menu.
2. Touch FINISHER TESTS.
3. Touch Sensor Test.
4. Touch Media Path 1.
5. Touch Bridge unit media exit.
Does the display on the operator panel change every
time the sensing area of the above sensor is
interrupted or blocked?
3
Check the sensor (bridge unit media exit) connection.
Is the above component properly connected?
Yes
No
Replace the
Problem solved.
bridge unit
interface card
assembly.
Go to
"Bridge
unit interface
card assembly
removal" on
page
4-115.
Go to step 6.
Replace the
Problem solved.
finisher controller
card assembly.
Go to
"Finisher
controller card
assembly
removal" on
page
4-116.
Yes
No
Go to step 2.
Clean or replace
the bridge unit
assembly.
Go to
unit assembly
removal" on
page
Go to step 4.
Go to step 3.
Replace the
Replace the
sensor (bridge
connection.
unit media exit).
Go to
"Sensor
(bridge unit
media exit)
removal" on
page
4-17.
Diagnostic information
7500-XXX
"Bridge
4-5.
2-15

Advertisement

Table of Contents
loading

This manual is also suitable for:

X852eX854eX860deX862deX864de