Ratings, Dimensions, Data - Slant/Fin Galaxy GXH-300H Installation And Operating Instructions Manual

Gas-fired cast iron boilers for natural and l.p. propane gases
Hide thumbs Also See for Galaxy GXH-300H:
Table of Contents

Advertisement

2
Alternate 38 mm
(1-1/2") return
(except GG-75
thru GG-175
FRONT VIEW
All GG and GXH
GG SERIES HOT WATER BOILERS—DIMENSIONS IN MM FOLLOWED BY INCHES
GG-75H
GG-100H
GG-125H
A
502
19
/
502
19
/
502
19
/
3
3
3
46
46
46
B
335
13
/
335
13
/
335
13
/
3
3
3
16
16
16
C
127
5
152
6
152
6
66/6
66/6
66/6
D
1178
46
/
1353
53
/
1353
53
/
3
1
1
86
46
46
E
171
6
/
330
13
/
330
13
/
3
1
1
46
46
46
F
203
8
203
8
203
8
66/6
66/6
66/6
G
32
1
/
32
1
/
32
1
/
1
1
1
46
46
46
H
38
1
/
38
1
/
38
1
/
1
1
1
26
26
26
J
70
2
/
70
2
/
70
2
/
3
3
3
46
46
46
K
235
9
/
235
9
/
235
9
/
1
1
1
46
46
46
GXH SERIES STEAM AND HOT WATER BOILERS - DIMENSIONS IN MM FOLLOWED BY INCHES
GXH-105
GXH-125
GXH-150
A
584
23
584
23
673
26
66/6
66/6
B
421
16
/
421
16
/
506
19
9
9
16
16
C
127
5
152
6
178
7
66/6
66/6
D
1178
46
/
1353
53
/
1410
55
3
1
86
46
E
171
6
/
330
13
/
356
14
3
1
46
46
F
248
9
/
248
9
/
286
11
3
3
46
46
G
32
1
/
32
1
/
32
1
1
1
46
46
H
64
2
/
64
2
/
64
2
1
1
26
26
J
89
3
/
89
3
/
89
3
1
1
26
26
K
248
9
/
248
9
/
248
9
3
3
46
46
L
13
/
13
/
13
1
1
26
26
273 mm
/
(10
")
3
4
152 – 327 mm (6 – 12-7/8")
832 mm
337 mm
(13
622 mm
/
)
1
(24
"
2
LEFT SIDE
All GG and GXH
ORIFICE SIZES indicated for Sea Level are factory installed in boiler unless other-
wise specified by the local authority.
See VII, page 12 for burner input adjustment.
GAS VALVE CONNECTION Size is 13 mm (1/2") f.p.t. for all sizes up to and
including GG-125 and GXH-125 depending upon configuration (natural, L.P .,
standing pilot, IID). Larger boilers, gas valves are 19 mm (3/4").
COMBUSTIBLE FLOOR KIT increases all height dimensions by 51 mm (2").
RAISED SLAB—When mounting boiler on a raised slab, the slab must extend at
least 51 mm (2") beyond the boiler cabinet on all sides.
CHIMNEY HEIGHT: 4.5 m (15 ft.) minimum from draft hood skirt to top of
chimney. CHIMNEY INSIDE DIAMETER must be same as Dimension "C" or
larger. Larger diameter and/or height may be required if two or more boilers or a
boiler and another appliance are vented to a single chimney.
RIGHT SIDE
GG / GXH-PT
GG-150H
GG-175H
GG-200H
GG-225H
584
23
584
23
673
26
/
673
1
66/6
66/6
222
421
16
/
421
16
/
506
19
/
506
9
9
15
16
16
16
152
6
152
6
178
7
178
66/6
66/6
22/22
1353
53
/
1353
53
/
1461
57
/
1461
1
1
1
46
46
222
330
13
330
13
406
16
406
66/6
66/6
22/22
248
9
/
248
9
/
286
11
/
286
3
3
1
46
46
422
32
1
/
32
1
/
32
1
/
32
1
1
1
46
46
422
38
1
/
38
1
/
38
1
/
38
1
1
1
26
26
222
70
2
/
70
2
/
70
2
/
70
3
3
3
46
46
422
235
9
/
235
9
/
235
9
/
235
1
1
1
46
46
422
GXH-170
GXH-190
GXH-210
/
673
26
/
673
26
/
756
29
1
1
1
3
266
266
266
/
506
19
/
506
19
/
592
23
15
15
15
9
16
16
16
178
7
178
7
178
7
66/66
66/66
66/66
66/6
/
1410
55
/
1410
55
/
1410
55
1
1
1
1
266
266
266
356
14
356
14
356
14
66/66
66/66
66/66
6/66
/
286
11
/
286
11
/
286
11
1
1
1
1
466
466
466
/
32
1
/
32
1
/
32
1
1
1
1
1
466
466
466
/
64
2
/
64
2
/
64
2
1
1
1
1
266
266
266
/
89
3
/
89
3
/
89
3
1
1
1
1
266
266
266
/
248
9
/
248
9
/
248
9
3
3
3
3
466
466
466
/
13
/
13
/
19
1
1
1
3
266
266
266
Install
Manual
Shut-Off
Valve 1524
mm (5 ft.)
Above
When
Required
By Local
Code
57
mm
/
)
1
(2
"
4
/
(32
3
")
4
419 mm
/
)
1
(16
"
2
/
)
1
"
4
57 mm
/
)
1
(2
"
4
FRONT VIEW
All GG and GXH
Pressure
Relief
Valve
19 mm (
/
")
3
4
13 mm (
/
')
1
2
Vent
Tapping
RIGHT SIDE
GXH-PZT-PPZT
GG-250H
GG-275H
GG-300
26
/
756
29
/
756
29
/
845
1
3
3
222
46
46
19
/
592
23
/
592
23
/
662
15
5
5
16
16
16
7
203
8
203
8
203
22/22
66/6
66/6
57
/
1514
59
/
1514
59
/
1514
1
5
5
222
86
86
16
432
17
432
17
432
22/22
6/66
6/66
11
/
330
13
330
13
375
1
422
66/6
66/6
1
/
32
1
/
32
1
/
32
1
1
1
422
46
46
1
/
38
1
/
38
1
/
38
1
1
1
222
26
26
2
/
70
2
/
70
2
/
70
3
3
3
422
46
46
9
/
235
9
/
235
9
/
235
1
1
1
422
46
46
GXH-230
GXH-250
GXH-275
826
32
/
/
756
29
/
826
32
/
3
1
1
46
46
26
26
662
26
/
/
592
23
/
662
26
/
9
1
1
16
16
16
16
178
7
178
7
178
7
6/66
66/6
6/66
/
1410
55
/
1410
55
/
1410
55
/
1
1
1
26
26
26
26
356
14
356
14
356
14
6/66
6/66
6/66
375
14
/
/
330
13
/
375
14
/
1
3
3
46
46
46
46
/
32
1
/
32
1
/
32
1
/
1
1
1
46
46
46
46
/
64
2
/
64
2
/
64
2
/
1
1
1
26
26
26
26
89
3
/
/
89
3
/
89
3
/
1
1
1
26
26
26
26
248
9
/
/
248
9
/
248
9
/
3
3
3
46
46
46
46
/
19
/
19
/
19
/
3
3
3
46
46
46
46
Tankless Heater
Connections "L"
GXH-PT only
318 mm
/
1
(12
2
Return
Tapping G on
right side of
boiler
673 mm
/
)
1
(26
"
2
76
mm
(3")
184 mm
/
1
(2
")
4
RIGHT SIDE
GG / GXH-PT
BOILER MODEL
GG/GX
Propane
Except GG-399H
GG-399H
Propane
GXH-105
through 275
Propane
GXH-300
Propane
GXH-300H
GG-350H
*For L.P . Propane gas, consult factory.
RIGHT SIDE
GXH-PZ
GG-325
GG-350
GG-350H
33
/
845
33
/
927
36
/
927
36
1
1
1
44
44
24
26
/
662
26
/
764
30
/
764
30
1
1
1
16
16
16
8
203
8
229
9
229
9
44/4
44/4
4/44
59
/
1680
66
/
1680
66
/
1680
66
5
1
1
84
84
84
17
432
17
572
22
/
572
22
1
44/4
44/4
24
14
/
375
14
/
413
16
/
413
16
3
3
1
44
44
44
1
/
32
1
/
32
1
/
32
1
1
1
1
44
44
44
1
/
38
1
/
38
1
/
38
1
1
1
1
24
24
24
2
/
70
2
/
70
2
/
70
2
3
3
3
44
44
44
9
/
235
9
/
235
9
/
235
9
1
1
1
44
44
44
GXH-300
GXH-300H
826
32
/
32
/
826
1
1
26
26
662
26
/
26
/
662
1
1
16
16
203
8
229
9
6/66
6/66
127mm
1718
67
/
1502
59
/
5
1
(5")
86
86
635
25
15
381
152mm
6/66
6/66
(6")
375
14
/
14
/
375
3
3
46
46
178mm
(7")
32
1
/
32
1
/
1
1
46
46
203mm
64
2
/
64
2
/
1
1
26
26
(8")
89
3
/
3
/
89
1
1
228mm
26
26
(9")
248
9
/
9
/
248
3
3
46
46
254mm
19
/
19
/
(10")
3
3
46
46
Tankless Heater
Connections "L"
except GXH-PZ
318
mm
/
)
1
32 mm (1
"
)
/
"
70 mm
4
1
(12
"
Tapping on
2
/
)
3
(2
"
4
Steam Boilers
660
648 mm
mm
/
)
1
(25
"
2
)
(26"
419 mm
/
1
)
(16
"
2
184
mm
/
1
(7
")
4
RIGHT SIDE
GXH--PZ-PZT-PPZT
ORIFICE SIZES AT HIGH ALTITUDES
610 to 1219 m
Orifice Size for
GAS TYPE
Sea Level
(2000 to 4000 ft.)
Natural
42
43
54
55
Natural
40
42
53
54
Natural
44
43
54
55
Natural
43
44
55
54
Natural
43
44
Gas*
GALAXY
GG-375
GG-375H
GG-399H
/
927
36
/
927
36
/
927
36
/
1
1
1
1
24
24
24
24
/
764
30
/
764
30
/
764
30
/
1
1
1
1
16
16
16
16
229
9
254
10
254
10
4/44
4/44
4/44
4/44
/
1680
66
/
1680
66
/
1680
66
/
1
1
1
1
84
84
84
84
/
381
22
/
381
22
/
457
22
/
1
1
1
1
24
24
24
24
/
413
16
/
413
16
/
413
16
/
1
1
1
1
44
44
44
44
/
32
1
/
32
1
/
32
1
/
1
1
1
1
44
44
44
44
/
38
1
/
38
1
/
38
1
/
1
1
1
1
24
24
24
24
/
70
2
/
70
2
/
70
2
/
3
3
3
3
44
44
44
44
/
235
9
/
235
9
/
235
9
/
1
1
1
1
44
44
44
44
Effikal Damper
C
H
I
152mm
122mm
(6")
(4-13/16")
165mm
135mm
(6-1/2")
(5-5/16")
179mm
149mm
(7-1/16")
(5-7/8")
205mm
175mm
(8-1/16")
(6-7/8")
276mm
225mm
(10-7/8")
(8-7/8")
327mm
276mm
(12-7/8") (10-7/8")
70
)
mm
/
)
3
(2
"
4
660
mm
)
(26"
1219 to 1372 m
(4000 to 4500 ft.)
43
55
42
54
45
55
44
56
44

Advertisement

Table of Contents
loading

Table of Contents