WATER INLET (RETURN) - 1" NPT (MALE)
WATER OUTLET (SUPPLY) - 1" NPT (MALE)
5 3/8
2 1/2
23
17 3/4
REAR VIEW
Figure 1. Dimensions data
SPECIFICATIONS FOR LX-85 BOILER
Fuel Rate Input:
Boiler Water Volume:
Water Piping Connections: 1" NPT (male)
Gas Piping Connection:
Vent Connection:
Air Intake Connection:
Weight of Boiler (uncrated): 105 lbs.
Gas orifice size:
*Note: No orifice changes are required for high altitude installations.
**See page 43 for conversion procedure to propane.

RATINGS AND DIMENSIONS

6 7/8
1 1/2
2 5/8
36 3/4
3 3/8
85,000 BTUH maximum
25,000 BTUH minimum
.75 gallon (6.25 lbs)
1/2" NPT (female)
3" nominal I.D. pipe (PVC, CPVC or stainless steel)
3" nominal I.D. pipe (PVC, CPVC or stainless steel)
Natural Gas - No orifice used *
Propane - 0.190" diameter **, ID Code: C
27 7/8
VENT CONNECTION
12 3/8
33 7/8
16 1/4
7
23 3/4
SIDE VIEW
Lynx Model LX-85
AIR INTAKE
CONNECTION
GAS SHUTOFF
VALVE
1/2" NPT
(FEMALE)
23 5/8
FRONT VIEW
Figure 2. Lynx Boiler
4 3/4
8 5/8
41