Communication operation and setting
List of calibration parameters
Para
Name
meter
C2
Terminal 2 frequency
(902)
setting bias frequency
C3
Terminal 2 frequency
(902)
setting bias
125
Terminal 2 frequency
(903)
setting gain frequency
C4
Terminal 2 frequency
(903)
setting gain
C5
Terminal 4 frequency
(904)
setting bias frequency
C6
Terminal 4 frequency
(904)
setting bias
[Special monitor selection No.]
Refer to page 152 for details of the monitor description.
Data
Description
H01
Output frequency/speed
H02
Output current
H03
Output voltage
Frequency setting value/speed
H05
setting
*4
H06
Running speed
H08
Converter output voltage
H09
Regenerative brake duty
Electronic thermal relay function
H0A
load factor
H0B Output current peak value
H0C Converter output voltage peak value
H0D Input power
H0E Output power
H0F
Input terminal status
H10
Output terminal status
H11
Load meter
H14
Cumulative energization time
............... Specifications differ according to the date assembled. Refer to page 378 to check the SERIAL number.
*1
Input terminal monitor details
b15
*2
Output terminal monitor details
b15
*3
The setting depends on capacities. (55K or lower/75K or higher)
*4
When Pr.37 = "1 to 9998" or Pr. 144 = "2 to 10, 102 to 110," the unit is an integral value (one increment). (Refer to page 150)
*5
Option input terminal 1 monitor details (input terminal status of FR-A7AX)-all terminals are OFF when an option is not fitted
b15
X15
X14
X13
*6
Option input terminal 2 monitor details (input terminal status of FR-A7AX)-all terminals are OFF when an option is not fitted
b15
*7
Option output terminal monitor details (output terminal status of FR-A7AY)-all terminals are OFF when an option is not fitted
b15
244
Instruction code
Read
Write
Extended
5E
DE
5E
DE
5F
DF
5F
DF
60
E0
60
E0
Unit
0.01Hz/1
*4
0.01A/0.1A
0.1V
0.01Hz/1
1r/min
0.1V
0.1%
0.1%
0.01A/0.1A
0.1V
0.01kW/
0.1kW
*3
0.01kW/
0.1kW
*3
*1
*2
0.1%
1h
CS
RES
STOP
X12
X11
X10
X9
RA3
Para
meter
126
Terminal 4 frequency
1
(905)
setting gain frequency
C7
Terminal 4 frequency
1
(905)
setting gain
C42
PID display bias coefficient
1
(934)
C43
PID display bias analog
1
(934)
value
C44
PID display gain coefficient
1
(935)
C45
PID display gain analog
1
(935)
value
Data
Description
H17
Actual operation time
H18
Motor load factor
*3
H19
Cumulative power
H32
Power saving effect
H33
Cumulative saving power
H34
PID set point
H35
PID measured value
H36
PID deviation
H3A Option input terminal status 1
H3B Option input terminal status 2
*3
H3C Option output terminal status
32-bit cumulative power
H4D
(lower 16-bit)
32-bit cumulative power
H4E
(upper 16-bit)
32-bit cumulative power
H4F
(lower 16-bit)
32-bit cumulative power
H50
(upper 16-bit)
MRS
JOG
RH
RM
ABC2
ABC1
X8
X7
X6
X5
RA2
RA1
Y6
Y5
Instruction code
Name
Read
61
61
22
22
23
23
Unit
1h
0.1%
1kWh
Variable
Variable
0.1%
0.1%
0.1%
*5
*6
*7
1kWh
1kWh
0.01kWh/
0.1kWh
0.01kWh/
0.1kWh
RL
RT
AU
STR
FU
OL
IPF
X4
X3
X2
Y4
Y3
Y2
Write
Extended
E1
1
E1
1
A2
9
A2
9
A3
9
A3
9
*1
*1
b0
STF
b0
SU
RUN
b0
X1
X0
b0
DY
b0
Y1
Y0