Frequency setting by external terminals

4.7 Frequency setting by external terminals

Purpose
Make frequency setting by
combination of terminals
Perform jog operation
Added compensation for multi-speed
setting and remote setting
Infinitely variable speed setting by
terminals
4.7.1

Multi-speed setting operation (Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239)

Can be used to change the preset speed in the parameter with the contact terminals.
Any speed can be selected by simply turning ON/OFF the contact signals (RH, RM, RL, REX signals).
Parameter
Number
4
Multi-speed setting (high speed)
5
Multi-speed setting (middle speed)
6
Multi-speed setting (low speed)
Multi-speed setting (speed 4)
24
*1
Multi-speed setting (speed 5)
25
*1
Multi-speed setting (speed 6)
26
*1
Multi-speed setting (speed 7)
27
*1
232
Multi-speed setting (speed 8)
*1
233
Multi-speed setting (speed 9)
*1
234
Multi-speed setting (speed 10)
*1
235
Multi-speed setting (speed 11)
*1
236
Multi-speed setting (speed 12)
*1
237
Multi-speed setting (speed 13)
*1
238
Multi-speed setting (speed 14)
*1
239
Multi-speed setting (speed 15)
*1
The above parameters allow their settings to be changed during operation in any operation mode even if "0" (initial value) is set in Pr. 77 Parameter write selection.
*1
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 201)
*2
Performing IPM parameter initialization changes the settings. (Refer to page 80)
(1) Multi-speed setting (Pr. 4 to Pr. 6)
⋅ Operation is performed at the frequency set in Pr. 4 when the RH signal turns ON, Pr. 5 when the RM signal turns
ON, and Pr. 6 when the RL signal turns ON.
Speed 1
(High speed)
Speed 2
(Middle speed)
Speed 3
(Low speed)
ON
RH
ON
RM
ON
RL
REMARKS
⋅ In the initial setting, if two or three speeds are simultaneously selected, priority is given to the set frequency of the lower signal.
For example, when the RH and RM signals turn ON, the RM signal (Pr. 5) has a higher priority.
⋅ The RH, RM, RL signals are assigned to the terminal RH, RM, RL in the initial setting.
By setting "0 (RL)", "1 (RM)", "2 (RH)" in any of Pr.178 to Pr.189 (input terminal function assignment), you can assign the signals to
other terminals.
102
Multi-speed operation
Jog operation
Multi-speed input
compensation selection
Remote setting function
Initial
Name
Value
60Hz
30Hz
10Hz
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
Forward
rotation
Time
Multi-Speed Operation
Connection Example
Parameter that must be Set
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 232 to Pr. 239
Pr. 15, Pr. 16
Setting Range
0 to 400Hz
*2
0 to 400Hz
0 to 400Hz
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
0 to 400Hz, 9999
Inverter
STF
RH
10
RM
2
RL
5
SD
Refer to Page
Pr. 28
Pr. 59
Description
Set the frequency when RH turns ON.
Set the frequency when RM turns ON.
Set the frequency when RL turns ON.
Frequency from speed 4 to speed 15 can
be set according to the combination of
the RH, RM, RL and REX signals.
9999: not selected
102
104
106
106