3.5 RINGS AND TONES

3.5.1 RING CYCLES

The OfficeServ 7200-S provides the trunk line rings, station rings, door rings, and alarm rings.The ON/OFF cycle of
each ring is shown in the table below (it is different according to the country, and can be modified by MMC pro-
gramming).
3.5.1a SYSTEM RING CYCLES
RING
TRUNK LINE RING
STATION RING
DOOR RING
ALARM RING
Note: The ON/OFF cycle can be adjusted by changing the values of the system database.
3.5.2 RING
The output voltage and frequency of the ring signals in the OfficeServ 7200-S are as follows:
Output voltage: 75 Vrms Square Wave (Built in SLI)
Frequency: 20 or 25 Hz
The OfficeServ 7200-S provides the users with various tones to notify the users of the status of functional opera-
tions. The ON/OFF cycles of currently specified tones are shown in the table on the next page.

3.5.3 SYSTEM TONES

TONE
DIAL TONE
BUSY TONE
DO NOT DISTURB TONE
RING BACK TONE
CALL PARK TONE
CONFIRMATION/CAUTION/BARGE-IN TONE
CALL BACK/HOLD TONE
RING BACK TONE
ERROR/NUMBER UNOBTAINABLE TONE
MESSAGE CAMP ON TONE
Note: The ON/OFF cycle can be adjusted by changing the values of the system database.
ON/OFF CYCLE
1000/2000 ms
400/200/400/3000 ms
400/200/400/200/400/2000 ms
400/200/400/200/400/200/400/1000 ms
ON/OFF CYCLE
1000/250 ms
500/500 ms
250/250 ms
1000/2000 ms
CONTINUOUS
50/50 ms
500/3500 ms
1000/2000 ms
250/250 ms
CONTINUOUS