6.1.3
Temperature-setting adjustments
Set flow temperature at the control unit (fig. 8, item 6)
(see table 1).
Set hot-water temperature for 600 - 24 C with
integrated hot-water supply at knob (fig. 8, item 3)
(see table 2).
For energy saving (no heat-retention function) move
knob (fig. 8, item 3) to cold-start-setting "1".
Set outlet temperature, at the same time, to 60 °C.
Set hot-water temperature for 600 Series with
external tank at control unit (fig. 8, item 3) using
table 3.
Adjust room temperature to maximum setting at the
control unit.
Open the gas service valve by pushing in and turning
anticlockwise into a vertical position (fig. 8, item 4).
Push the mains power switch (fig. 8, item 1) to "I".
The boiler runs through the start-up programme and
the burner is ignited after approx. 30 seconds.
Adjust room temperature to desired setting at the
control unit.
Control unit
i
Buderus
RT30
ON/OFF temperature
controller, 24 V
*
Basic setting: Have the specific system settings of the Buderus control system and burner-control unit control panel adjusted by
a specialist heating system company.
Table 1
Flow temperature
Subject to modifications resulting from technical improvements!
Users manual for Buderus 600 - 11S / 19S / 24S / 24C • edition 02/2006
Range of application
Floor heating
Radiator heating
Radiator heating
1
I
0
6
1
10
1
5
Fig. 8
Control panel, pressure display, gas service valve,
temperature indicator
Controller position / boiler flow temperature
13
(48 °C, max. factory-adjusted setting for floor
heating)
17
(67 °C, min. factory-adjusted setting for radiator
heating)
15
(58 °C, new building) up to
10
(80 °C, old building)*