Buderus 600 - 11S User Manual page 5

Gas wall hung condensing boiler
Table of Contents

Advertisement

If necessary open the CH flow and CH return
maintenance valves (fig. 3, item 1 and 2).
Connect temporary hose (fig. 4).
Open both stop valves.
Fill the system to a pressure of 1.0 to 1.2 bar
(fig. 5, item 1). Max. water pressure is 1.5 bar.
Shut both stop valves and disconnect the filling loop.
Subject to modifications resulting from technical improvements!
Users manual for Buderus 600 - 11S / 19S / 24S / 24C • edition 02/2006
1