Trigger Shift

The camera can perform exposure by the next trigger
even during image transmission (except in Special
Trigger mode). In such case, as the trigger signal can be
a noise source, use the camera with Trigger Shift
activated. When Trigger Shift is active, the time between
trigger input and start of exposure is automatically
adjusted to avoid noise generation, causing a delay of
one line at maximum in starting exposure. When Trigger
Shift is deactivated, the delay adjustment is not made
and exposure always starts with the same timing, but
noise may be mixed into images. Even if Trigger Shift is
active, triggering may be disabled, or exposure may be
defective while an image transmission is in progress and
the next transmission cannot be started. Select a
sufficient trigger interval (see "Trigger Input
Specifications" (page 8)).
Setting parameter: TriggerShift = On
Trigger Shift operation (The figure below
shows Trigger Edge mode.)
1.5usec
Trigger signal
Exposure
Image output
Example of next image transmission
enabled
Transmission of the next image can be started as the
previous image transmission is already completed when
the exposure ends.
Trigger signal
Exposure
Image output
For More Information Please Call Aegis Electronic Group, Inc. * (888) 687-6877 Phone * aegis-g2@aegiselect.com * http://www.aegis-elec.com
14
To be shifted in this period
1H (26usec)
max 27.5usec
min 1.5usec
Next image
transmission starts
after transmission of the
previous image is
completed.
Example of next image transmission
disabled
As image transmission is not completed when the
exposure ends, transmission of the next image cannot be
started. The trigger becomes invalid.
Trigger signal
Exposure
Image output
Note
Trigger Shift cannot be enabled in Trigger Width/Exact
Time Exposure mode.

Trigger Inhibit

This function disables the camera's trigger input. When
multiple cameras are connected, use this to disable
triggering for only specified cameras or to eliminate
malfunction due to noise mixed in the trigger signal line
from the setup environment.
Setting parameter: TriggerInhibit = On
Trigger signal
Trigger
Inhibit
Exposure
Trigger disabled
Image output
Next image transmission
starts before transmission of
the previous image is
completed.
x
No image output
x