1.5

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY!
GD36 RATES AND EFFICIENCIES
Altitude (FT)
Max. Input
(BTU/HR)
Max. Output
(BTU/HR)
Effi ciency
(w/the fan on)
A.F.U.E.
Min. Inlet Gas
Supply Pres-
sure
Max. Inlet
Gas Supply
Pressure
Manifold
Pressure
(Under Flow
Conditions)
This fi replace is approved for bathroom, bedroom and bed-sitting room
installations and is suitable for mobile home installation.
No external electricity (110 volts or 24 volts) is required for the gas
system operation.
Expansion / contraction noises during heating up and cooling
down cycles are normal and are to be expected.
1.6

CARE OF GLASS

DO NOT CLEAN GLASS WHEN HOT! DO NOT USE ABRASIVE
CLEANERS TO CLEAN GLASS.
Buff lightly with a clean dry soft cloth. Clean the glass after the first 10
hours of operation with a recommended fireplace glass cleaner.
Thereafter clean as required. If the glass is not kept clean permanent
discoloration and / or blemishes may result.
1.7

CARE OF PLATED PARTS

If the appliance is equipped with plated parts, you must clean fi ngerprints or other marks from the plated
surfaces before operating the appliance for the fi rst time. Use a glass cleaner or vinegar and towel to clean.
If not cleaned properly before operating for the fi rst time, the marks can cause permanent blemishes on the
plating. After the plating is cured, the fi ngerprints and oils will not affect the fi nish and little maintenance is
required, just wipe clean as needed. Prolonged high temperature burning with the door ajar may cause a
permanent rain bowing effect on the lower edge of a gold plated door (applies to wood product only).
NOTE: The protective wrap on plated parts is best removed when the assembly is at room
temperature but this can be improved if the assembly is warmed, using a hair dryer or similar heat
source.
NG
0-4,500
0-4500
26,000
26,000
22,360
22,880
86%
64%
4.5" Water
11" Water
Column
Column
7" Water Column
13" Water
Column
3.5" Water
10" Water
Column
Column
BGD36 RATES AND EFFICIENCIES
LP
Altitude (FT)
Max. Input
(BTU/HR)
Max. Output
(BTU/HR)
88%
Effi ciency
(w/the fan on)
65%
A.F.U.E.
Min. Inlet Gas
Supply Pres-
sure
Max. Inlet
Gas Supply
Pressure
Manifold
Pressure
(Under Flow
Conditions)
NG
0-4,500
0-4,500
18,000
17,000
11,500
10,900
64%
53%
4.5" Water
11" Water
Column
Column
7" Water Column
13" Water
Column
3.5" Water
10" Water
Column
Column
66.4%
GD36
WARNING
!
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
5.1
6.1
W415-0210 / S / 03.10.09
7
LP
64%
53%