1.4

GENERAL INSTRUCTIONS

Always light the pilot whether for the first time or if the gas supply has ran out, with the glass door
Provide adequate accessibility clearance for servicing and operating the appliance.
Objects placed in front of the appliance must be kept a minimum of 48" from the front face of the unit.
This product must be installed by a licensed plumber or gas fitter when installed within the commonwealth
High Pressure will damage valve. Disconnect gas supply piping before pressure testing gas line at test pressures
above 1/2 psig. Close the manual shut-off valve before pressure testing gas line at test pressures equal to or
Use only Wolf Steel approved optional accessories and replacement parts with this appliance. Using non-listed
accessories (blowers, doors, louvres, trims, gas components, venting components, etc.) could result in a safety
THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local
codes. Installation practices vary from region to region and it is important to know the specifics that apply to your area, for
example in Massachusetts State:
• The appliance damper must be removed or welded in the open position prior to installation of a appliance insert or gas log.
• The appliance off valve must be a "T" handle gas cock.
• The flexible connector must not be longer than 36 inches.
• A Carbon Monoxide detector is required in all rooms containing gas fired appliances.
• The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed
combustion product.
The installation must conform with local codes or, in absence of
local codes, the National Gas and Propane Installation Code
CSA B149.1 in Canada, or the National Fuel Gas Code,
ANSI Z223.1 / NFPA 54 in the United States. Suitable for mobile
home installation if installed in accordance with the current
standard CAN/CSA Z240MH Series, for gas equipped mobile
homes, in Canada or ANSI Z223.1 and NFPA 54 in the United
States.
When the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood flooring, the
applinace shall be installed on a metal or wood panel extending the full width and depth.
If the optional fan or blower is installed, the junction box must be electrically connected and grounded in ac-
cordance with local codes. In the absence of local codes, use the current CSA C22.1 Canadian Electrical Code
in Canada or the ANSI/NFPA 70 National Electrical Code in the United States.
W415-0210 / S /03.10.09
WARNING
!
opened or removed.
Provide adequate ventilation.
Never obstruct the front opening of the appliance.
of Massachusetts.
Fire risk. Explosion Hazard.
less than 1/2 psig.
hazard and will void the warranty and certification.
We suggest that our gas
heart products be installed
and serviced by professionals
who are certified in the U.S.
by the National Appliance
Institute ® (NFI) as NFI Gas
Specialists
www.nficertified.org